PRIME D
PRIME D

Description

  • Innovative digital controllers dedicated to normal and low temperature refrigerated applications
  • Direct line power supply 230(110)Vac. No external transformer required
  • Direct driving of compressors up to 1,2 HP(20A relay inside)
  • Pre-programming of the main control variables
  • Easy and intuitive programming mode
  • Keyboard lock, alarm signalling by relay, display or buzzer
  • Configurable digital input for door switch, defrost, general or serious alarm
  • Ausiliary relay activated through keys or digital input
  • Hot Key for easy and fast programming
  • HACCP function
  • 3VA max power absorption
  • Display with red LED (13,2mm high)

See Manual Download links at the bottom of this page

Models

 

 THERMOSTAT AND CONTROLLERS FOR NORMAL, MEDIUM AND LOW TEMPERATURE

 
XR10D


THERMOSTAT WITH HEATING OR COOLING ACTION
D: 4 DIN Rail

Generals
N° digits display:
± 3 d.p.
Power supply: 24, 110, 230Vac

Probe inputs
Thermostat:
NTC/PTC

Digital inputs
Alarm, start defrost, auxiliary, door switch, pressure switch:
configurable

Relay outputs
Compressor:
8A 20A optional

Other
Buzzer:
optional
Functions: HACCP
Hot Key output: present

XR20D


DIGITAL CONTROLLER FOR N.T. WITH "OFF CYCLE" DEFROST
D: 4 DIN Rail  

Generals
N° digits display:
± 3 d.p.
Power supply: 24, 110, 230Vac

Probe inputs
Thermostat
: NTC/PTC

Digital inputs
Alarm, start defrost, auxiliary, door switch, pressure switch:
configurable

Relay outputs
Compressor:
8A 20A opzional

Other
Buzzer:
optional
Functions: HACCP
Hot Key output: present

XR30D


DIGITAL CONTROLLER FOR N.T. WITH "OFF CYCLE" DEFROST AND ADDITIONAL CONFIGURABLE RELAY
D: 4 DIN Rail 

Generals
N° digits display:
± 3 d.p.
Power supply: 24, 110, 230Vac

Probe inputs
Thermostat:
NTC/PTC

Digital inputs
Alarm, start defrost, auxiliary, door switch, pressure switch:
configurable

Relay outputs
Alarm or auxiliary:
8A
Compressor: 8A 20A optional

Other
Buzzer:
optional
Functions: HACCP
Hot Key output: present

XR40D


DIGITAL CONTROLLER FOR MT AND LT WITH ELECTRICAL OR HOT GAS DEFROST
D: 4 DIN Rail

Generals
N° digits display:
± 3 d.p.
Power supply: 24, 110, 230Vac

Probe inputs
Defrost:
NTC/PTC
Thermostat: NTC/PTC

Digital inputs
Alarm, start defrost, auxiliary, door switch, pressure switch:
configurable

Relay outputs
Compressor:
8A 20A optional
Defrost: 8A

Other
Buzzer:
optional
Functions: HACCP
Hot Key output: present

 

 CONTROLLERS FOR MEDIUM AND LOW TEMPERATURE AND FOR MILK TANK CONTROLLERS

 
XR60D


DIGITAL CONTROLLER FOR MT AND LT VENTILATED APPLICATIONS WITH DOOR SWITCH CAPABILITY
D: 4 DIN Rail

Generals
N° digits display:
± 3 d.p.
Power supply: 24, 110, 230Vac

Probe inputs
Defrost:
NTC
Thermostat: NTC

Digital inputs
Alarm, start defrost, auxiliary, door switch, pressure switch:
configurable

Relay outputs
Compressor:
8A, 20A optional
Defrost: 8A
Fans: 8A

Other
Buzzer:
optional
Functions: HACCP
Hot Key output: present

XR70D

 
DIGITAL CONTROLLER FOR MT AND LT VENTILATED APPLICATIONS WITH DOOR SWITCH CAPABILITY AND AUXILIARY RELAY
D: 4 DIN Rail

Generals
N° digits display:
± 3 d.p.
Power supply: 24, 110, 230Vac

Probe inputs
Defrost:
NTC
Thermostat: NTC

Digital inputs
Alarm, start defrost, auxiliary, door switch, pressure switch:
configurable

Relay outputs
Alarm or auxiliary:
8A
Compressor: 8A 20A optional
Defrost: 8A
Fans: 8A

Other
Buzzer:
optional
Functions: HACCP
Hot Key output: present

XR80D

 
DIGITAL CONTROLLER FOR MILK TANK REFRIGERATORS WITH AGITATION CYCLE CAPABILITY
D: 4 DIN Rail

Generals
N° digits display:
± 3 d.p.
Power supply: 24, 110, 230Vac

Probe inputs
Thermostat:
NTC/PTC

Relay outputs
Agitator:
8A
Compressor: 8A 20A optional

Other
Buzzer:
optional
Functions: min/max
Hot Key output: present

Manual Download

On this page we offer you to view or download existing documentation and print them at your desk.

model name click on the flag of your desired document language
 XR10D             
 XR20D             
 XR30D                    
 XR40D                
 XR60D                   
 XR70D              
 XR80D              

Go to Top