PRIME CX
PRIME CX

Description    

  • Innovative digital controllers dedicated to heat and NT and LT refrigeration
  • Easy and intuitive programming mode
  • On/off key
  • Energy saving cycles through digital input
  • Fast freezing with dedicated set point
  • Outputs restart with door open alarm
  • Temperature Max and Min functions
  • Configurable digital input also as probe
  • Virtual probe management
  • C​ycles for milk cooling and storage systems
  • Functions for refrigerated air dryers in automation processes
  • Condenser temperature management to prevent critical plant situations
  • Hot Key or Prog Tool Kit connector for quick and easy programming
  • Serial connection to monitoring systems (direct for XR35/75/77CX or via XJ485CX)
  • Connection for X-REP remote display (alternative to TTL output)
  • 3VA max power absorption
  • Display with red LED (10,5mm high) and icons

See Manual Download links at the bottom of this page.

 Models    

 

 REFRIGERATION CONTROLLERS

 
XR10CX

XR10Cx_device

THERMOSTAT WITH HEATING OR COOLING ACTION

Generals
Power supply:
12, 24Vac/dc, 24, 110, 230Vac

Probe inputs
Thermostat:
NTC, PTC
Condenser (on HOT KEY): NTC, PTC

Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch, probe: configurable

Relay outputs
Compressor:
8A, 20A 

Other
Hot Key / Prog Tool Kit output:
present
Remote display output: X-REP optional
Serial output: TTL
Buzzer: optional

XR10CX_sch

XR20CX

XR20CX

CONTROLLER FOR NT WITH "OFF CYCLE" DEFROST

Generals
Power supply:
12, 24Vac/dc, 24, 110, 230Vac

Probe inputs
Thermostat:
NTC, PTC
Condenser (on HOT KEY): NTC, PTC

Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch, probe: configurable

Relay outputs
Compressor:
8A, 20A 

Other
Hot Key / Prog Tool Kit:
present
Remote display output: X-REP optional
Serial output: TTL
Buzzer: optional

XR20CX_sch

XR30CX

XR30CX_dev

CONTROLLER FOR NT WITH "OFF CYCLE" DEFROST AND ADDITIONAL CONFIGURABLE RELAY

Generals
Power supply:
12, 24Vac/dc, 24, 110, 230Vac

Probe inputs
Thermostat:
NTC, PTC
Condenser (on HOT KEY): NTC, PTC

Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch, probe: configurable

Relay outputs
Compressor:
8A, 20A
Light/Alarm:
8A


Other
Hot Key / Prog Tool Kit:
present
Remote display output: X-REP optional
Serial output: TTL
Buzzer: optional
RTC: optional

XR30CX_sch

XR35CX

XR35CX_dev

CONTROLLER FOR NT WITH "OFF CYCLE" DEFROST, ADDITIONAL CONFIGURABLE RELAY AND RS485

Generals
Power supply:
110, 230Vac

Probe inputs
Thermostat:
NTC, Pt1000
Defrost: NTC, Pt1000
Condenser: NTC, Pt1000

Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch, probe:
configurable
Alarm, start defrost, AUX, door switch, pressure switch: configurable

Relay outputs
Compressor:
8A, 16A
Light/Alarm: 8A

Other
Hot Key / Prog Tool Kit:
present
Remote display output:
X-REP
Serial output:
RS485
Buzzer: optional
RTC: optional

XR35CX_sch

XR40CX

XR40CX_dev

CONTROLLER FOR NT AND LT WITH ELECTRICAL OR HOT GAS DEFROST

Generals
Power supply:
12, 24Vac/dc, 24, 110, 230Vac

Probe inputs
Thermostat:
NTC, PTC
Defrost: NTC, PTC
Condenser (on HOT KEY): NTC, PTC

Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch, probe:
configurable

Relay outputs
Compressor: 8A, 20A
Defrost:
8A


Other
Hot Key / Prog Tool Kit:
present
Remote display output: X-REP optional
Serial output: TTL
Buzzer: optional

XR40CX_sch.jpg

XR60CX

XR60CX_dev

CONTROLLER FOR NT AND LT VENTILATED APPLICATIONS WITH DUAL HUMIDITY FUNCTION

Generals
Power supply:
12, 24Vac/dc, 24, 110, 230Vac

Probe inputs
Thermostat:
NTC, PTC
Defrost: NTC, PTC
Condenser (on HOT KEY): NTC, PTC

Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch, probe:
configurable

Relay outputs
Compressor:
8A, 16A, 20A*
Defrost: 8A
Fans: 8A, 5A*
* With Comp. 20A: Defrost 8A, Fans 5A, Power supply 110, 230Vac

Other
Hot Key / Prog Tool Kit:
present
Remote display output: X-REP optional
Serial output: TTL
Buzzer: optional

XR60CX_sch

XR70CX

XR70CX_dev 

CONTROLLER FOR NT AND LT VENTILATED APPLICATIONS WITH AUXILIARY RELAY AND WITH DUAL HUMIDITY FUNCTION

Generals
Power supply:
12Vac/dc, 110, 230Vac

Probe inputs
Thermostat:
NTC, PTC
Defrost: NTC, PTC
Condenser (on HOT KEY): NTC, PTC

Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch, probe:
configurable

Relay outputs
Compressor:
8A, 16A*
Defrost: 8A, 16A*
Fans: 5A, 16A*
Light/Alarm: 8A, 16A*
* With Power supply 12Vac/dc: Comp. 16A, Defrost 16A, Fans 16A, Light/Alarm 16A

Other
Hot Key / Prog Tool Kit:
present
Remote display output: X-REP optional
Serial output: TTL
Buzzer: optional
RTC: optional

XR70CX_sch 

XR75CX

XR75CX_dev

CONTROLLER FOR NT AND LT VENTILATED APPLICATIONS WITH AUXILIARY RELAY, DUAL HUMIDITY FUNCTION AND RS485

Generals
Power supply:
110, 230Vac

Probe inputs
Thermostat:
NTC, Pt1000
Defrost: NTC, Pt1000
Condenser: NTC, Pt1000

Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch, probe:
configurable
Alarm, start defrost, AUX, door switch, pressure switch: configurable

Relay outputs
Compressor:
8A, 16A 
Defrost: 8A
Fans: 5A
Light/Alarm: 8A

Other
Hot Key / Prog Tool Kit:
present
Remote display output: X-REP
Serial output: RS485
Buzzer: optional
RTC: optional

XR75CX_sch 

XR77CX

 XR77CX_dev

CONTROLLER FOR NT AND LT VENTILATED APPLICATIONS WITH AUXILIARY RELAY, DUAL HUMIDITY FUNCTION, RS485 AND RELAY WITH SEPARATED COMMON LINES

Generals
Power supply:
12, 24Vac/dc or 110, 230Vac

Probe inputs
Thermostat:
NTC, Pt1000
Defrost: NTC, Pt1000
Condenser: NTC, Pt1000

Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch, probe:
configurable
Alarm, start defrost, AUX, door switch, pressure switch: configurable

Relay outputs
Compressor:
8A, 12A
Defrost: 12A
Fans: 5A
Light/Alarm: 7A

Other
Hot Key / Prog Tool Kit:
present
Remote display output: X-REP
Serial output: RS485
Buzzer: optional
RTC: optional

XR77CX_sch
XR80CX
XR80CX_dev 
DIGITAL CONTROLLER FOR STORAGE, MILK COOLING, AND FOR REFRIGERATED AIR DRYERS
 
Generals
Power supply: 12Vac/dc or 110, 230Vac
 
Probe inputs
Thermostat: NTC, PTC
 
Digital inputs
Alarm, start defrost, AUX, door switch, pressure switch: configurable
 
Relay outputs
Compressor: 8A, 20A
Agitator: 8A
 
Other
Hot Key / Prog Tool Kit: present
Serial output: TTL
Buzzer: optional
 
 
XR80CX_sch
 
 
    Manual Download   

    On this page we offer you to view or download existing documentation and print them at your desk.

     

    model name click on the flag of your desired document language
     XR10CX                                                 
     XR20CX                                          
     XR30CX                                         
     XR35CX                                                                        
    XR40CX                                                        
    XR60CX                                           
    XR70CX                                                 
    XR75CX                                                                
    XR30CX + RTC                               
    XR35CX + RTC​                                      
    XR70CX + RTC                                                              
    XR77CX + RTC                                                 
    XR80CX​ ​                  

     

    Know more information about Prime CX series.

     

    Know more about Prime CX Accessories.
     
     prime+frame
     

     Go To Top

     

     

    PrimeCX device