XRB
XRB

Description 

  • Electronic controllers for bottle cooler
  • Easy and intuitive installation
  • High energy saving thanks to load optimization
  • Algorithms for energy saving work without the use of external sensors
  • Energy saving based on pre-set time interval
  • Automatic set point management after filling the cabinet
  • Compressor working time control
  • Counters of compressor/defrost/fans/light activation time
  • Condenser monitor for maintenance management
  • Anti-sweat heaters management (only for XRB07CX)
  • Firmware update via special Prog Key
  • Hot Key or Prog Tool Kit connector for quick and easy programming
  • Serial connection to monitoring systems
  • 3VA max power absorption
  • Display with red LED (10,5mm high) and icons

See Manual Download links at the bottom of this page.

Models

CONTROLLERS FOR STATIC OR VENTILATED BOTTLE COOLER APPLICATIONS
XRB04CX

XRB04CX
DIGITAL CONTROLLER FOR STATIC APPLICATIONS
CX: 32x74mm 
 
Generals
Display: n° digits: ± 3 d.p.
Power supply: 12Vac/dc, 110, 230Vac
 
Probe inputs
Thermostat: NTC
Defrost: NTC
Condenser: NTC
 
Digital inputs
Start defrost, light, AUX, door switch, energy saving, probe: configurable
Alarm, start defrost, light, AUX, door switch, energy saving, fans, ON/OFF: configurable
 
Relay outputs
Compressor: 16A
Light: 8A
 
Other
Hot Key/Prog Tool Kit output: present
Serial output: TTL
Buzzer: optional

XRB04CX connections 

XRB06CX

​​XRB06CX
DIGITAL CONTROLLER FOR VENTILATED APPLICATIONS
CX: 32x74mm
 
Generals
Display: n° digits: ± 3 d.p.
Power supply: 12Vac/dc, 110, 230Vac
 
Probe inputs
Thermostat: NTC
Defrost: NTC
Condenser: NTC
 
Digital inputs
Start defrost, light, AUX, door switch, energy saving, probe: configurable
Alarm, start defrost, light, AUX, door switch, energy saving, fans, ON/OFF: configurable
 
Relay outputs
Compressor: 16A
Fans: 8A
Light: 8A
 
Other
Hot Key/Prog Tool Kit output: present
Serial output: TTL
Buzzer: optional

XRB06CX connections 

XRB07CX

XRB07CX

DIGITAL CONTROLLER FOR VENTILATED APPLICATIONS WITH AUXILIARY OUTPUT
CX: 32x74mm
 
Generals
Display: n° digits: ± 3 d.p.
Power supply: 110, 230Vac
 
Probe inputs
Thermostat: NTC
Defrost: NTC
Condenser: NTC
Condenser/AUX: NTC on HOT KEY
 
Digital inputs
Start defrost, light, AUX, door switch, energy saving, probe: configurable
Alarm, start defrost, light, AUX, door switch, energy saving, fans, ON/OFF: configurable
 
Relay outputs
Compressor: 16A
Fans: 8A
Light: 8A
AUX: 5A
 
Other
Hot Key/Prog Tool Kit output: present
Serial output: TTL
Buzzer: optional

XRB07CX connections 

​​Manual Download 

On this page we offer you to view or download existing documentation and print them at your desk.

model name​ ​click on the flag of your desired document language
XRB04CX Italian​     English
​​XRB06CX Italian     English
​XRB07CX Italian     ​English
 