EazyCool Technical Details
 
 
OMTQ-60 - TFD
Cooling Capacity at Standard Condition 11.23kW
R407C, Evaporating -10°C, Ambient 32°C, Superheat 10K, Subcooling 0K (Dew Point data)
 
Mechanical Data
Condenser/Fan TypeV9 6P/145 Number of Fans2.0
Total Fan Power Input, Watts290.0 Depth/Width, mm670/2100
Height, mm950.0 Gross Weight, kg244.0
Net Weight, kg209.0 Receiver Capacity, l17.7
Liquid Line, inch5/8 Air Flow, cu.m/sec1.8
High Side PS, bar(g)26.2 Low Side PS, bar(g)21.0
Suction TypeCu Tube Suction Diameter, inch1 3/8
Base mounting (hole dia), mm1330 x 620 (12) Sound Pressure @ 10m, dBA42.0
 
Electrical Data
Condenser Fan Current for 1 fan (single phase)0.67 / 0.9 Compressor Maximum Operating Current, A2 x 10.30
Compressor Locked Rotor Current, A2 x 49.3  
 
Accessoires
Crankcase Heater2 x 70W External
Oil separatorALCO OSH-407
LP SwitchALCO PS1 W3A (Automatic reset)
HP SwitchALCO PS3 WF4 (Automatic reset)
Liquid sight glassALCO AMI-1SS5-5/8S
Liquid solenoid valveALCO 200RBT5 shipped loose
Compressor contactorABB A16-30-01
Internal Suction LineInsulated
Fan speed controlALCO FSP150
Sound attenuationCompressor blanket
Filter DrierALCO ADK Plus
Main Isolator Switch32A
Electronic controlerALCO EC2 551
Sound attenuationCompressor blanket
Fan speed controlALCO FSP150
Internal Suction LineInsulated
Liquid solenoid valveALCO 200RBT5 shipped loose
Compressor contactorABB A16-30-01
Crankcase Heater2 x 70W External
Oil separatorALCO OSH-407
LP SwitchALCO PS1 W3A (Automatic reset)
HP SwitchALCO PS3 WF4 (Automatic reset)
Liquid sight glassALCO AMI-1SS5-5/8S
Electronic controlerALCO EC2 551
Main Isolator Switch32A
Filter DrierALCO ADK Plus
 
Related Documentation
Catalogue
Copeland EazyCool™: Outdoor Scroll Condensing Units
General Product Catalogue 2017
 
Technical Information
Fans for Condensing Units
Oil additives
 
Application Guidelines
Copeland EazyCool™ Outdoor Condensing Units
Condensing Unit Controller EC2-5XX for Copeland EazyCool Outdoor Condensing Units
 
Old declarations (before April 2016)
OCU OM: Declaration of Incorporation according to the Machinery Directive 2006/42/EC
OCU OM: Conformity Declaration CE 06 according to the Low Voltage Directive 2006/95/EC
OCU OM: Conformity Declaration according to the RoHS Directive 2011/65/EU
 
Wiring Diagramms
Wiring diagram Network Condensing Unit OMTQ, OLTQ - TF
Legend
 
Declarations (after April 2016)
EU Declaration of Incorporation according to the Machinery Directive 2006/42/EC for Eazycool large outdoor Units
 
Related Compressor
2xZB30KCE   
 
 
 
Share