myREEFER Supported Functionalities
Print
myREEFER Supported Functionalities 

FAQ image If you don't find an answer to your question, please contact us so we can help you.

Click on the links below to view answers. The myREEFER supported functionalities are detailed on the tables below.

Which GPRS data is sent on a scheduled basis?
 
Which data is event-driven?
 

Current Level of GPRS Support

Function

ThermoKing*
(MP-4000/3000)
Carrier
(Microlink 3/2i)
Starcool*
(RCCU5/SCC6)
Daikin
(Decos III c/d)
Scheduled condition data (temperatures, humidity, positioning) Yes Yes Yes Yes
Event driven data (reefer alarms, Power ON/OFF, setpoint changes) Yes Yes Yes Yes
Initiate PTI (Full or brief) Yes Yes Yes Yes
Start trip Yes Yes Yes N/A1
Start manual defrost Yes Yes Yes Yes
Retrieve full data log Yes Yes Yes Yes
Update controller firmware Yes N/A2 Yes Yes
Change temperature setpoint Yes Yes Yes Yes
Change humidity setpoint Yes Yes Yes Yes
Ping container for latest status Yes Yes Yes Yes

1 Daikin controller does not support remote trip start setting
2 Carrier controller does not support remote firmware upload

Current Level of ISO10368 Support

Function

ThermoKing*
(MP-4000/3000)
Carrier
(Microlink 3/2i)
Starcool*
(RCCU5/SCC6)
Daikin
(Decos III c/d)
Polling of condition data (temperatures, humidity, alarms) Yes Yes Yes Yes
Change temperature setpoint Yes Yes Yes Yes
Change humidity setpoint Yes Yes Yes Yes
Change container ID Yes Yes Yes Yes
Initiate defrost Yes Yes Yes Yes
Change O2 and CO2 setpoints Yes Yes Yes Yes
Ping container for latest status Yes Yes Yes Yes

Current Level of Bluetooth Support

Function

ThermoKing*
(MP-4000/3000)
Carrier
(Microlink 3/2i)
Starcool*
(RCCU5/SCC6)
Daikin
(Decos III c/d)
Quick status using RDC+ handheld (temperatures, alarms) Yes Yes Yes Yes

*Thermo King and Star Cool must be updated to compatible firmware release prior to use of RMM+

Reporting Scheme

Reefer container power state

Description

Wake up on motion Motion sensor enabled Alive interval
ON Uses 1 hour "alive interval" to report to GMS. Reports immediately on events such as alarms and change of setpoint. 1 hour
OFF (0-12 hours) Wakes up and reports to GMS with alive interval of 1 hour or wake up on motion is detected Yes Yes 1 hour
OFF (12-48 hours) Wakes up and reports to GMS with alive interval of 4 hours. RMM+ does not use motion sensor to wake up on movement in this state, but only detects if the RMM+ has moved with the alive interval. No Yes 4 hours
OFF (48-168 hours) Wakes up and reports to GMS with alive interval of 4 hours. Only obtains GPS fix once per 12 hours if the motion sensor indicates no movement. If the motion sensor If the motion sensor indicates movement, then it obtains GPS position and reports to GMS. No Yes 4 hours
OFF(>168 hours) wakes up and report to GMS with alive interval of 24 hours. Motion sensor is not enabled in this state. No No 24 hours