24A01G-3 Level-Temp Silent Operator For Low Voltage Control Of Electric Heat

  • 240 VAC, 60Hz Input
  • SPST, Normally Open
  • 45 Second Average Time Delay

Catalog Page

 

 

24A01Z-10 Level Temp Low Voltage

  • Single Level Temps - Normally Open, 347 VAC

Installation Instructions
Catalog Page

 

 

24A05A-1 Level-Temp Silent Operator For Low Voltage Control Of Electric Heat

  • 120 VAC, 60Hz Input
  • SPST Normally Open
  • 45 Second Delay

Installation Instructions
Catalog Page

 

 

24A05E-1 Level Temp Silent Operator For Low Voltage Control Of Electric Heat

  • 208 VAC, 60Hz Input
  • SPST Normally Open
  • 45 Second Delay

Installation Instructions
Catalog Page

 

 

24A05Z-1 Level Temp Silent Operator For Low Voltage Control Of Electric Heat

  • 277 VAC, 60Hz Input
  • SPST, Normally Open
  • 45 Second Delay

Installation Instructions

 

 

24A07E-1 Level Temp Silent Operator For Low Voltage Control Of Electric Heat

  • 208 VAC,60Hz Input
  • SPST, Normally Open
  • 45 Second Delay
  • Skeleton Construction (No Enclosure)

Installation Instructions

 

 

24A07G-1 Level Temp Silent Operator For Low Voltage Control Of Electric Heat

  • 240 VAC,60Hz Input
  • SPST, Normally Open
  • 45 Second Average Time Delay,
  • Skeleton Construction

Installation Instructions

 

 

24A06G-1 Level Temp Silent Operator For Low Voltage Control Of Electric Heat

  • 240 VAC, 60Hz Input
  • DPST, Normally Open
  • 45 Second Average Time Delay

Installation Instructions
Catalog Page

 

 

24A34-1 Electric Heat Sequencer

  • 1 Switch
  • On Timings, 1-20 Sec.
  • Off Timings, 40-110 Sec.

Installation Instructions
Catalog Page

 

 

24A34-2 Electric Heat Sequencer

  • 1 Switch
  • On Timings, 30-90 Sec.
  • Off Timings, 1-30 Sec.

Installation Instructions
Catalog Page

 

 

24A34-3 Electric Heat Sequencer

  • 2 Switches
  • On Timings, 1-20 Sec.
  • Off Timings, 40-110 Sec.

Installation Instructions
Catalog Page

 

 

24A34-4 Electric Heat Sequencer

  • 2 Switches
  • On Timings, 30-90 Sec.
  • Off Timings, 1-30 Sec.

Installation Instructions
Catalog Page

 

 

24A34-5 Electric Heat Sequencer

  • 3 Switches
  • On Timings, 1-110 Sec.
  • Off Timings, 1-110 Sec.

Installation Instructions 
Catalog Page

 

 

24A34-6 Electric Heat Sequencer

  • 4 Switches
  • On Timings, 1-110 Sec. Off Timings, 1-110Sec.

Installation Instructions
Catalog Page

 

 

24A34-14 Electric Heat Sequencer

  • 5 Switches
  • On Timings, 1-160 Sec.
  • Off Timings, 1-160 Sec.

Installation Instructions
Catalog Page

 

 

24A34-15 Electric Heat Sequencer

  • Used In Heat Pump Air Handler Applications
  • 1 Switch
  • On Timings, 1-60 Sec. Off Timings, 75-95 Sec.

Installation Instructions 
Catalog Page

 

 

24A34-21 Electric Heat Sequencer

  • Single Timing
  • Heat On in 1 to 20 Seconds
  • Heat Off in 1 to 50 Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page

 

 

24A34-22 Electric Heat Sequencer

  • Single Timing
  • Heat On in 15 to 45 Seconds
  • Heat Off in 1 to 30Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page

 

 

24A34-23 Electric Heat Sequencer

  • Single Timing
  • Heat On in 25 to 55 Seconds
  • Heat Off in 15 to 45 Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page

 

 

24A34-24 Electric Heat Sequencer

  • Single Timing
  • Heat On in 30 to 75 Seconds
  • Heat Off in 1 to 40 Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page

 

 

24A34-25 Electric Heat Sequencer

  • Single Timing
  • Heat On in 40 to 90 Seconds
  • Heat Off in 1 to 30 Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page

 

 

24A34-26 Electric Heat Sequencer

  • Double Timing, Double Pole
  • Heat On in 1 to 20 Seconds / 30 to 90 Secconds
  • Heat Off in 40 to 90 Seconds / 1 to 30 Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page

 

 

24A34-27 Electric Heat Sequencer

  • Combination Relay 2 on Single Plate
  • Heat On in 1 to 160 Seconds
  • Heat Off in 1 to 160 Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page

 

 

24A34-28 Electric Heat Sequencer

  • Combination Relay 2PDT
  • Heat On in 1 to 160 Seconds
  • Heat Off in 1 to 160 Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page

 

 

24A34-29 Electric Heat Sequencer

  • Single Timing
  • Heat On in 15 to 35 Seconds
  • Heat Off in 25 to 55 Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page

 

 

24A34-36 Electric Heat Sequencer

  • Double Timing, Double Pole
  • Heat On in 1 to 20 Seconds / 30 to 45 Secconds
  • Heat Off in 45 to 110 Seconds / 1 to 30 Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page

 

 

24A34-37 Electric Heat Sequencer

  • Double Timing, Double Pole
  • Heat On in 1 to 110 Seconds
  • Heat Off in 1 to 110 Seconds
  • Double Quick Connect Terminals for Combination Loads
  • -40° to +150°F (-40° to +66°C) Ambient

Catalog Page